CPAP 20E Basic therapy for sound sleep Weinmann's best-priced CPAP20e guarantees effective CPAP therapy- and thus healthy sleep. User-friendliness and economy are the watchwords for the simple and efficient operating functions. Specifications User-friendly Simple, proven three-button operationTrouble-free cleaningQuietLight, only 1.25 kgPressure constancyLeakage compensationUse of standard tubeAnalysis of compliance data with PC software SOMNO supportData-related compliance data with or with out humidifier for 365 daysRemote setting with SOMNO adjust or SOMNO support Functions Soft start function (5 to 30 minutes)Two-level filter systemSafe oxygen feedAutomatic altitude adjustmentExternal power pack can be used world wide with 100-240 VOptional DC adapter for 12V/24V, also for use with a humidifierAvailable option- humidifier CLICK 2 Attaches to therapy device with a simple "Click"Holds 280 ml of waterSix-level setting on therapy deviceEasy to clean Device Description WM No CPAP20e 27320 Humidifier CLICK 2 27330 Accessories Transport Bag- WM 27335DC adapter, 12V/24V-WM 24469Bacteria filter- WM 24476O2-Valve- WM 24042 safety oxygen feed Technical Data CPAP 20e Product class as per directive 93/42/EEC lla Dimensions (WXHXD) 210X98X185 mm Weight Approx, 1.25 kg Temperature range Operation +5oC to +35oC Storage -20oC to +70oC if the device is operated at +40oC the expelled air could reach a temperature of up to 42oC Allowed humidity, operation and storage 95% relative humidity (no condensation) Air pressure range 600-1100 hpa (Automatic altitude compensation) Connection diameter Respiratory hose (mask side) 19.5 mm (Suitable for 22 mm norm conus) Electrical connection 115-230 V AC +10/-15%50-60 HZ with power pack WM24480 or 12-24V DC-15/+25%With DC adapter WM 24469 Current consumption at 230V, 115V, 24V, 12V Operation 0.1A, 0.2A, 0.8A, 1.6A Standby 0.02A, 0.03A, 0.2A, 0.24A Classification according to prEN 60601-1:2004 Protection from electric shock protection class II Degree of protection from electric shock Type B Protection from water penetration damage IPX1 Type of operation Permanent usage Electromagnetic compatibility (EMV) as per EN 60601-1-2 Test parameters and limit may be requested from manufacturer as needed Radio interference suppression EN 55011B Radio interference resistance EN 61000-4 part 2 to 6, part 11 Mean sound pressure level operation in patient position, about one meter from the device /< 30dB (A) at 10 hPa CPAP operating pressure range 4 to 20hpa Pressure accuracy + 0.8 hpa (1 mbar=1hpa~1cm H2O) Max. CPAP pressure in case of breakdown <40 hpa Flow at max. speed at 20 hpa- 130 l/min15 hpa- 140 l/min10 hpa- 160 l/min5 hpa- 175 l/min0 hpa- 185 l/min Tolerance + 15 l/min Warming of ambient air 2.5oC Short-term pressure constancy as per prEN ISO 17510: 2004 at < 10hpa>10 hpa p=0.5hpap=1.0 hpa Long-term pressure cdonstancy as per EN 17510-1: 2004 p=0.2 hpa Fine filter separation level up to 1 mup to 0.3 m > 99.5%> 85% Fine filter service life > 250 hours with normal ambient air