voice search
Laboratory Laminar Air Flow - Mica Top And Anodized Aluminum Frame, 6mm Glass Side Panels, 220 Volt, Complete With Hepa Filters And Uv Light
Share

Laboratory Laminar Air Flow - Mica Top And Anodized Aluminum Frame, 6mm Glass Side Panels, 220 Volt, Complete With Hepa Filters And Uv Light

Price: 53100.00 INR / Unit

(45000.00 INR + 18% GST)

Get Latest Price

MRP:

55000.00 INR / Unit

Weight :

75.00 Kilogram

1 Pack Contains :

1

Minimum Pack Size :

1

In Stock

In Stock

-1+

Product Specifications

Voltage220 Volt (v)
Frame MaterialAluminum
ConditionNew
ApplicationLaboratory
FOB PortINDIA
Payment TermsLetter of Credit (L/C), Telegraphic Transfer (T/T)
Supply Ability10 Per Month
Delivery Time20 Days
Sample PolicyContact us for information regarding our sample policy
Packaging DetailsWooden Packaging Required
Main Domestic MarketAll India
CertificationsISO AND CE CERTIFIED
GSTIN18%
Pkg Box Breadth60.00 in
Shipping Typeorder_percent
Moq1
Pkg Box Height36.00 in
MRP55000.00 INR
Product Unit1 Unit/Units
Weight75.00 Kilogram
Pkg Box Length48.00 in
Price Typefixed
Price45000.00 INR (Approx.)
Brand NameNSLI INDIA
CurrencyINR
Stock Quantity5
Packsize1
Shipping Rate20.00
Unit TypeUnit/Units
ReturnableNo
Mop1
Minimum Order Quantity1
Minimum Ordered Packs1

Product Overview

Key Features

Condition : New
Work table Material : Mica top/S.S. Top and side panels are
Glass Thickness : 6MM
Frame Material : Anodized Aluminum Angle
Blower Power : A H.P.
Voltage : 220 Volts 50 CY. AC Supply
Complete with HEPA Filters, Prefilters, Motor Blower, Manometer, and Gas Cock, Transparent Acrylic Sheet Front and Side Doors U.V.Light

About Laminar Air Flow : - To be frank, the words a laminar air flowa does not indicate any furniture, but a principle in fluid mechanics. When air moves through a given space in both unified direction and velocity, it is said that it has achieved laminar air flow. It comes from the word a laminaa that means that the air moves as one uniform body.

A laminar air flow cabinet, also known as a tissue culture hood, clean bench, biological safety cabinet, or simply laminar hood, is a work surface enclosed in a boxlike structure mechanized to flood the inside of the enclosure with clean, sterilized air flowing in a laminar manner. It looks something akin to a fume hood , but works the opposite way.

Whata s the difference between a fume hood and a laminar airflow cabinet?
A fume hood sucks air out of the work area. A laminar airflow cabinet sucks clean air into the work area.

This airflow has to be laminar in nature, because normally air flows in a very irregular nature. Normal a that is, turbulent air flow creates lots of eddies and vortices that wreak havoc on any sterile-air environment. They can gather and deposit particles from outside air on your beloved hard-worked culture and screw up your whole result. Thus, we drown the work area in air that moves as one body, in uniform velocity and direction, so that eddies and vortices dona t form. That is exactly what laminar airflow is.
The basic idea of a laminar airflow cabinet is to provide a safe, sterile, filtered air environment. It uses the following parts:

Enclosure
Work Surface
Prefilter/filter pad
Blower/fan
HEPA Filter
UV Lamp
These parts come together to make a laminar airflow cabinet. Using the blower or fan, the product sucks in room air from the front or top of the product. The air first passes through the prefilter or filter pad, which captures large dust particles from the air. Then it goes through the HEPA filter, which filters out all the fine particles and microbes. That filtered air then pours into the enclosure and washes over the work surface, clearing it of any suspended particles and microbes. You can use the UV lamp to further sterilize the work area by bathing it in deadly rays.

The air flow is kept laminar by way of constructing the product carefully, so that all parts of the air inside the enclosure flows in straight lines parallel to each other, in the same direction. The airflow can be horizontal or vertical in manner, depending upon what should be the purpose of the sterile hood a to keep the sample safe or to keep the user safe.
Vertical Laminar Airflow
In this more common, compact type, the air flow is from top to bottom. The filters and the fan/blower is mounted on top of the product. The air can flow out the front of the enclosure after hitting the work surface, or the work surface can be perforated to let the air pass through and feed back up top into the primary filter.

Company Details

We offer a vast assortment of Laboratory Equipments & soil testing equipment that are technically accurate in function & precise in construct.? These equipment are available at industry leading prices and we can execute bulk orders efficiently and within less lead time. With an experience of years, Nand Scientific Instruments has registered a consistent growth over the years and is recognized as the most reliable manufacturer, supplier and trader of various Testing Equipments and Machines. Our range can be summed up as Laboratory Testing Equipment, Cement Testing Equipment, Concrete Testing Equipment, Soil Testing Equipment, Material Testing Equipment, Tile Testing equipment, Bitumen Testing Equipment, Aggregate Testing Equipment and many more. Located at Delhi, Standard Scientific Instruments, under the management of Mr. Mukesh Sundriyal, the organization has established a brand name in this highly competitive and sensitive market. We have made it possible by offering high standards of quality, accuracy, technical superiority, durability and performance of the equipment & being a quality driven organization.Cement,Soil,Bitumen & lab instruments companies

Business Type

Exporter, Manufacturer, Service Provider, Supplier, Trading Company, Wholesaler

Employee Count

10

Establishment

2012

Working Days

Monday To Sunday

GST NO

07COZPS8928E1ZY

Payment Mode

Cash Advance (CA), Cash in Advance (CID), Telegraphic Transfer (T/T)

Certification

ISO 9001 2015

Related Products

Explore Related Categories

Seller Details

GST

GST - 07COZPS8928E1ZY

Delhi, Delhi

Ceo

Mr. Ankit

Address

GH 1 794, SANSKRITI APARTMENT, SECTOR 28, ROHINI, Delhi, Delhi, 110042, India

laminar air flow in Delhi

Report incorrect details

More Product From This seller

Compare With Similar Products

Buyer Feedback

5

5

Minimum Order Quantity

1 Unit/Units

1 Piece/Pieces

Sample Policy

Contact us for information regarding our sample policy

Contact us for information regarding our sample policy

Main Domestic Market

All India

Maharashtra

Payment Terms

Telegraphic Transfer (T/T)

Cash Against Delivery (CAD)

People Also Viewed