voice search
Need
Help
Pendants Multi Door Interlocking Systems
SharePDF

Pendants Multi Door Interlocking Systems

Price:

Get Latest Price

In Stock

In Stock

Product Overview

Key Features

Multi Door Interlocking Systems 1. DESCRIPTION:             In clean room areas, any personnel passing through an unclassified area to a classified area is required to       pass through series of rooms. In each room certain steps need to be followed. This procedure ensures that the person is not carrying any external contamination in to the process area and also the pressure in each room is maintained before opening of door. Door Inter Locking System achieves in prevention of process area contamination by   Preventing simultaneous access of doors/Rooms.   Ensures that when one door for a room is OPEN then all other doors in that particular room are closed.   Programmable delay between each door openings to maintain required pressure.   In Emergency an override key is available on a push button module for opening the door. 2. CONTROLLER FEATURES:   Advanced Micro controller based.   Supports Maximum of 12 doors & 24 Push buttons.   Supports Maximum of 12 Emergency Stations.   Sequence of door inter Locking is field configurable.   Delay between door openings is field configurable from 0 to 999 Sec.   Auto close time is field configurable from 0 to 999 Sec.   Facility available to read feed back from Magnetic Lock.   8x2 DOT MATRIX LCD for Programming.   Easy use Soft touch Tactile Membrane keypad & user-friendly programming options.   Non-Volatile Flash memory to store programming parameters.   Supports Access control module interface.  SPECIFICATIONS:   GENERAL   Push Button Inputs                  :           12 No.   Door Feedback Inputs             :           12 No, 24V.   Door Control Outputs              :           12 No, 24V / 25mA   Keypad                                                :           Soft touch Tactile Membrane Keys, 4.   Display                                                :           8x2 Alphanumeric LCD.   Memory                                   :           Non-Volatile Flash.   Delay between each door        :           Programmable 0 to 999 Sec.   Door control sequencing          :           Programmable. ENCLOSURE:   Enclosure type                         :           MS (Siemens gray, Powder coated)..   Mounting                                 :           Flush / Panel / Wall mounting. POWER:   Power source                           :           100 to 260 V, AC 50 Hz. ENVIORMENTAL:   Temperature                            :           0 to 500C.   RH                                           :           10 95%, Non-condensing. MECHANICAL:   Weight                                     :           approx. 1Kg.   Dimensions                              :           495X295X50 mm  OPERATION:          Key operation   :  Increment key: To increment the parameter value.   :  Right shift key: To shift the cursor position to the right side. OK: To enter a particular program parameter. PRG: To enter into program mode and to exit the program mode.            PROGRAM MODES S.NO           MODE              DESCRIPTION 1 Auto Lock To select time between the door release and re- energizing the lock as required. 2 nC All doors to be in Normally Open/Normally Close position 3 Emrgency Configure the doors for Emergency. 4 DI Configure the Door 1. 5 DII Configure the Door 2. 6 DIII Configure the Door 3. 7 DIV Configure the Door 4. 8 DV Configure the Door 5. 9 DVI Configure the Door 6. 10 DVII Configure the Door 7. 11 DVIII Configure the Door 8. 12 New Psd. To Enter new password.             press PRG To enter the new password and store all parameters

Company Details

Styrax Instruments India Pvt. Ltd. has become a leading player in the market of latest technology range of security systems. We stand as a key Manufacturer, Exporter and Supplier of a huge range of Clean Room Process Monitor (Temp, RH, DP), Door Interlocking Systems, Clean Room Process Monitor (Temp, RH), Digital Differential Pressure Indicator, Pass box Interlocking System, Synchronized Digital Clocks, etc. Our array of Clean Room Process Monitor (Temp, RH, DP) includes 3- Channel Clean Room Process Monitor (Temp, RH, DP). We design the range of 3- Channel Clean Room Process Monitor (Temp, RH, DP) using advanced Microcontroller with inbuilt features of RH, Temperature & DP measurement. In ad

Business Type

Manufacturer, Service Provider, Supplier

Employee Count

100

Establishment

2010

Working Days

Monday To Sunday

GST NO

36AANCS6577L1ZF

Related Products

Explore Related Categories

Industry Leader

Seller Details

GST

GST - 36AANCS6577L1ZF

Hyderabad, Telangana

Managing -director

Mr Ram Bandi

Members since

1 Years

Address

Ho. No 2-77; Sy No 229; Gajularamaram, Hyderabad, Telangana, 500055, India

door interlocking system in Hyderabad

Report incorrect details

More Product From This seller

Compare With Similar Products

Payment Terms

Letter of Credit (L/C)

Letter of Credit (L/C)

People Also Viewed