Introduction: VLF HV testers are the new generation of AC hipot testers but with an output frequency of 0.1 Hz or lower rather than 50/60Hz. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, rather than 50Hz, it takes 500 times less current and power to apply an AC voltage to a capacitive load, like a long cable. There is no better way to verify the AC integrity of a cable than to hipot it with AC voltage. Now very Low Frequency (VLF) testing is internationally accepted as a safe and effective method for testing high voltage facilities. Not only for cable testing, but also spreading rapidly to others where similar benefits are evident, such as transformers, generators and etc. FSVLF series VLF HV testers are microprocessor controlled, have automatic functions for stepping-up, stepping-down, measuring and protecting. They are portable, light weight and small volume. Output waveform is clearly displayed on the large LCD and test report can be printed by built-in thermal printer. Technical parameters 1. Rated output voltage / current: See Details as following table 2. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz 3. Measurement accuracy: 3% 4. Positive and negative voltage peak errors: 3% 5. Voltage wave form distortion: 5% 6. Use condition: indoor and outdoor, temperature: -10 ~ +40, humidity: 85% 7. Input power: AC 50Hz, 220V 5% (this can be customized as requested) 8. Power supply fuse tube: See Details as following table Model No. Rated Voltage/current Load Capacitance Fuse Configuration and Reference Weight FSVLF-30 30kV/20mA Peak 0.1Hz,1.1F 5A Controller: 4kg 30kV Booster: 25 kg 0.05Hz,2.2F 0.02Hz,5.5F FSVLF-50 50kV/30mA Peak 0.1Hz,1.1F 15A Controller: 4 kg 50kV Booster: 50 kg 0.05Hz,2.2F 0.02Hz,5.5F FSVLF-60 60kV/30mA Peak 0.1Hz,0.5F 15A Controller: 4 kg Booster 1 (30kV): 25 kg Booster 2 (30kV): 25 kg 0.05Hz,1F 0.02Hz,2.5F FSVLF-80 80kV/30mA Peak 0.1Hz,0.5F 20A Controller: 4 Booster 1 (30kV): 25 kg Booster 2 (50kV): 50 kg 0.05Hz,1F 0.02Hz,2.5F Features: 1. Data of current, voltage, and waveform are directly sampled at high voltage side, so the data is real and accurate. 2. Overvoltage protection: If output exceeds the set limit of voltage, the instrument will shut-down to protect itself, the actuation time is less than 20ms. 3. Over current protection: it is high-low voltage dual protection in the design, the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut-down protection, the actuation time are both less than 20ms. 4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside. Accessories: 1. Connecting cables and wires 2. Power supply fuse tubes 3. Discharging rod 4. 50nF Compensation capacitor 5. Print paper 6. Factory test report 7. Instruction manual